mirror of
https://gitee.com/langsisi_admin/serein-flow
synced 2026-04-04 15:26:34 +08:00
示例工程版本提升至net462,项目添加了部分空引用检测逻辑。累了,消不完的空引用警告(T.T)
This commit is contained in:
231
Net462DllTest/Utils/ToValue.cs
Normal file
231
Net462DllTest/Utils/ToValue.cs
Normal file
@@ -0,0 +1,231 @@
|
||||
using IoTClient;
|
||||
using IoTClient.Clients.PLC;
|
||||
using IoTClient.Enums;
|
||||
using Net462DllTest.Signal;
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using System.Runtime.CompilerServices;
|
||||
using System.Text;
|
||||
using System.Threading.Tasks;
|
||||
|
||||
namespace Net462DllTest.Utils
|
||||
{
|
||||
internal static class MyPlcExtension
|
||||
{
|
||||
public static DataTypeEnum ToDataTypeEnum(this PlcVarInfo varInfo)
|
||||
{
|
||||
Type dataType = varInfo.DataType;
|
||||
DataTypeEnum plcDataType;
|
||||
switch (dataType)
|
||||
{
|
||||
case Type _ when dataType == typeof(string):
|
||||
plcDataType = DataTypeEnum.String;
|
||||
break;
|
||||
case Type _ when dataType == typeof(char):
|
||||
plcDataType = DataTypeEnum.String;
|
||||
break;
|
||||
case Type _ when dataType == typeof(bool):
|
||||
plcDataType = DataTypeEnum.Bool;
|
||||
break;
|
||||
case Type _ when dataType == typeof(float):
|
||||
plcDataType = DataTypeEnum.Float;
|
||||
break;
|
||||
case Type _ when dataType == typeof(double):
|
||||
plcDataType = DataTypeEnum.Double;
|
||||
break;
|
||||
case Type _ when dataType == typeof(byte):
|
||||
plcDataType = DataTypeEnum.Byte;
|
||||
break;
|
||||
case Type _ when dataType == typeof(short):
|
||||
plcDataType = DataTypeEnum.Int16;
|
||||
break;
|
||||
case Type _ when dataType == typeof(ushort):
|
||||
plcDataType = DataTypeEnum.UInt16;
|
||||
break;
|
||||
case Type _ when dataType == typeof(int):
|
||||
plcDataType = DataTypeEnum.Int32;
|
||||
break;
|
||||
case Type _ when dataType == typeof(uint):
|
||||
plcDataType = DataTypeEnum.UInt32;
|
||||
break;
|
||||
case Type _ when dataType == typeof(long):
|
||||
plcDataType = DataTypeEnum.Int64;
|
||||
break;
|
||||
case Type _ when dataType == typeof(ulong):
|
||||
plcDataType = DataTypeEnum.UInt64;
|
||||
break;
|
||||
default:
|
||||
plcDataType = DataTypeEnum.None;
|
||||
break;
|
||||
}
|
||||
|
||||
|
||||
return plcDataType;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// 读取设备的值
|
||||
/// </summary>
|
||||
/// <param name="client"></param>
|
||||
/// <param name="varInfo"></param>
|
||||
/// <returns></returns>
|
||||
/// <exception cref="Exception"></exception>
|
||||
public static object ReadToPlcValue(this SiemensClient client,PlcVarInfo varInfo)
|
||||
{
|
||||
Type dataType = varInfo.DataType;
|
||||
object resultvalue;
|
||||
if (dataType == typeof(string))
|
||||
{
|
||||
var result = client.ReadString(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(char))
|
||||
{
|
||||
var result = client.ReadString(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(bool))
|
||||
{
|
||||
var result = client.ReadBoolean(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(float))
|
||||
{
|
||||
var result = client.ReadFloat(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(double))
|
||||
{
|
||||
var result = client.ReadDouble(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(byte))
|
||||
{
|
||||
var result = client.ReadByte(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(short))
|
||||
{
|
||||
var result = client.ReadInt16(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(ushort))
|
||||
{
|
||||
var result = client.ReadUInt16(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(int))
|
||||
{
|
||||
var result = client.ReadInt32(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(uint))
|
||||
{
|
||||
var result = client.ReadUInt32(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(long))
|
||||
{
|
||||
var result = client.ReadInt64(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else if (dataType == typeof(ulong))
|
||||
{
|
||||
var result = client.ReadUInt64(varInfo.VarAddress);
|
||||
if (!result.IsSucceed) throw new Exception(result.Err);
|
||||
resultvalue = result.Value;
|
||||
}
|
||||
else
|
||||
{
|
||||
resultvalue = default;
|
||||
}
|
||||
return resultvalue;
|
||||
}
|
||||
|
||||
public static void WriteToPlcValue(this SiemensClient client, PlcVarInfo varInfo ,object value)
|
||||
{
|
||||
if(client == null) throw new ArgumentNullException("client");
|
||||
Type dataType = varInfo.DataType;
|
||||
Result result = null;
|
||||
if (dataType == typeof(string))
|
||||
{
|
||||
result = client.Write(varInfo.VarAddress, value.ToString());
|
||||
}
|
||||
else if (dataType == typeof(char))
|
||||
{
|
||||
result = client.Write(varInfo.VarAddress, value.ToString());
|
||||
}
|
||||
else if (dataType == typeof(bool))
|
||||
{
|
||||
var @bool = bool.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @bool);
|
||||
}
|
||||
else if (dataType == typeof(float))
|
||||
{
|
||||
var @float = float.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @float);
|
||||
}
|
||||
else if (dataType == typeof(double))
|
||||
{
|
||||
var @double = double.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @double);
|
||||
}
|
||||
else if (dataType == typeof(byte))
|
||||
{
|
||||
var @byte = byte.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @byte);
|
||||
}
|
||||
else if (dataType == typeof(short))
|
||||
{
|
||||
var @short = short.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @short);
|
||||
}
|
||||
else if (dataType == typeof(ushort))
|
||||
{
|
||||
var @ushort = ushort.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @ushort);
|
||||
}
|
||||
else if (dataType == typeof(int))
|
||||
{
|
||||
var @int = int.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @int);
|
||||
}
|
||||
else if (dataType == typeof(uint))
|
||||
{
|
||||
var @uint = uint.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @uint);
|
||||
}
|
||||
else if (dataType == typeof(long))
|
||||
{
|
||||
var @long = long.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @long);
|
||||
}
|
||||
else if (dataType == typeof(ulong))
|
||||
{
|
||||
var @ulong = ulong.Parse(value.ToString());
|
||||
result = client.Write(varInfo.VarAddress, @ulong);
|
||||
}
|
||||
if (result is null)
|
||||
{
|
||||
throw new Exception($"未定义的数据类型");
|
||||
}
|
||||
if(!result.IsSucceed)
|
||||
{
|
||||
throw new Exception(result.Err);
|
||||
}
|
||||
}
|
||||
|
||||
}
|
||||
}
|
||||
Reference in New Issue